-40%
Commscope Andrew L6PNF connector {NEW} N female 1 1/4" LDF6
$ 6.85
- Description
- Size Guide
Description
Brand new in-the-box Commscope/Andrew L6PNF connector (aka L46N/L46PN). N female for 1 1/4" LDF6 hardline. Standard two-piece, non-ring flare. No longer made since they have replaced LDF cable with the new AVA-style, so make sure you match the connectors with the right cable type!Shipping discount applied for multiples, so buy in bulk and save!
https://www.commscope.com/catalog/connectors/product_details.aspx?id=9446
Return Loss/VSWR
Frequency Band
VSWR
Return Loss (dB)
40–1000 MHz
1.02
39.00
1010–2200 MHz
1.03
38.00
2210–3300 MHz
1.04
34.00
General Specifications
Interface
N Female
Body Style
Straight
Mounting Angle
Straight
Electrical Specifications
Connector Impedance
50 ohm
Operating Frequency Band
0 – 3300 MHz
Average Power at Frequency
0.6 kW @ 900 MHz
Cable Impedance
50 ohm
3rd Order IMD at Frequency
-120 dBm @ 910 MHz
3rd Order IMD Test Method
Two +43 dBm carriers
RF Operating Voltage, maximum (vrms)
707.00 V
dc Test Voltage
2000 V
Outer Contact Resistance, maximum
0.30 mOhm
Inner Contact Resistance, maximum
2.00 mOhm
Insulation Resistance, minimum
5000 MOhm
Peak Power, maximum
10.00 kW
Insertion Loss, typical
0.05 dB
Shielding Effectiveness
-130 dB
Mechanical Specifications
Outer Contact Attachment Method
Ball clamp
Inner Contact Attachment Method
Captivated
Outer Contact Plating
Trimetal
Inner Contact Plating
Gold
Attachment Durability
25 cycles
Interface Durability
500 cycles
Interface Durability Method
IEC 61169-16:9.5
Connector Retention Tensile Force
1779 N | 400 lbf
Connector Retention Torque
10.85 N-m | 96.00 in lb
Insertion Force
66.72 N | 15.00 lbf
Insertion Force Method
MIL-C-39012C-3.12, 4.6.9
Pressurizable
No
Dimensions
Nominal Size
1-1/4 in
Diameter
51.99 mm | 2.05 in
Length
78.99 mm | 3.11 in
Weight
472.00 g | 1.04 lb
Environmental Specifications
Operating Temperature
-55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature
-55 °C to +85 °C (-67 °F to +185 °F)
Immersion Depth
1 m
Immersion Test Mating
Unmated
Immersion Test Method
IEC 60529:2001, IP68
Water Jetting Test Mating
Unmated
Water Jetting Test Method
IEC 60529:2001, IP66
Moisture Resistance Test Method
MIL-STD-202F, Method 106F
Mechanical Shock Test Method
MIL-STD-202F, Method 213B, Test Condition C
Thermal Shock Test Method
MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method
MIL-STD-202F, Method 204D, Test Condition B
Corrosion Test Method
MIL-STD-1344A, Method 1001.1, Test Condition A
Standard Conditions
Attenuation, Ambient Temperature
20 °C | 68 °F
Average Power, Ambient Temperature
40 °C | 104 °F